Beijing Qingchang power Technology Co.,Ltd

Beijing Qingchang power Technology Co.,Ltd

Manufacturer from China
Verified Supplier
1 Years
Home /

Products

/

QEFG Series Eco-friendly Gas Insulated RMU

Contact Now
Beijing Qingchang power Technology Co.,Ltd
Visit Website
City:beijing
Province/State:beijing
Country/Region:china
Contact Person:Miss
Contact Now
1 - 10 of 13

 Products

35kV Eco Friendly Gas Insulated Metal Enclosed Switchgear C-GIS

Typical primary plan An optional solution with a rated short-time breaking current of 1250A and a rated current of 25kA: An optional solution with a ....
Contact Now

Add to Cart

35kV SF6 Gas Insulated Metal Enclosed Switchgear C-GIS

Typical primary plan An optional solution with a rated short-time breaking current of 1250A and a rated current of 25kA: An optional solution with a ....
Contact Now

Add to Cart

24kV Eco Friendly Gas Insulated Metal Enclosed Switchgear C-GIS

Typical primary plan An optional solution with a rated short-time breaking current of 1250A and a rated current of 25kA: An optional solution with a ....
Contact Now

Add to Cart

24kV SF6 Gas Insulated Metal Enclosed Switchgear C-GIS

Typical primary plan An optional solution with a rated short-time breaking current of 1250A and a rated current of 25kA: An optional solution with a ....
Contact Now

Add to Cart

35kV QLG Series SF6 Gas Insulated RMU

Typical primary plan Rated Parameters S/N Name Unit Load switchgear C Circuit breaker cabinet V Combined electric cabinet F 1 Rated voltage kV 35.0 2 ...
Contact Now

Add to Cart

24kV QLG Series SF6 Gas Insulated RMU

Typical primary plan Rated Parameters Product Overview QLG series ring main unit is a SF6 gas insulated metal enclosed switchgear independently ...
Contact Now

Add to Cart

24kV QEFG Series Eco Friendly Gas Insulated RMU

Typical primary plan Rated Parameters S/N Name Unit 1 Rated frequency Hz 50/60 2 Rated voltage kV 24 3 Rated short-time power frequency withstand ...
Contact Now

Add to Cart

10kV SF6 Gas Insulated Metal Enclosed Switchgear C-GIS

Typical primary plan An optional solution with a rated short-time breaking current of 1250A and a rated current of 25kA: An optional solution with a ....
Contact Now

Add to Cart

QCB-101 Relay

Product Overview Phase and ground (E)/ fault (F) overcurrent protection Transformer high-temperature/over-temperature protection Records: Faults (200)...
Contact Now

Add to Cart

10kV Eco Friendly Gas Insulated Metal Enclosed Switchgear C-GIS

Typical primary plan An optional solution with a rated short-time breaking current of 1250A and a rated current of 25kA: An optional solution with a ....
Contact Now

Add to Cart

Inquiry Cart 0